Preview

Alternative Energy and Ecology (ISJAEE)

Advanced search
Open Access Open Access  Restricted Access Subscription or Fee Access

Experimental investigation of the influence of inclination on the power of a thermosiphon heat exchanger (TPCT)

https://doi.org/10.15518/isjaee.2024.11.117-121

Abstract

In the course of the work for experiments and efficiency studies, the previously developed unit was modified and experimental studies were carried out in the flow range from 0,4 to 1,15 l/s for heating and heated media for the design boiling point of the intermediate coolant in closed two-phase evacuated water-filled thermosiphons equal to 60 °C. It has . been established that the use of a thermal siphon in an inclined position is more effective for heat transfer. It is shown that the effect of inclination on the power of a thermosiphon heat exchanger depends on the boiling mode of the working £ fluid, maximum when operating in bubble boiling and minimum when operating in projectile and hypershell modes                                                                                                                                                                                                                  

About the Author

L. O. Iakovlev
Ural Federal University named after the first President of Russia B. N. Yeltsin
Russian Federation

Iakovlev Leonid Olegovich, postgraduate student

Yekaterinburg, Mira st., 19



References

1. Efficient heat exchangers with two-phase thermosiphons / I. L. Pioro, V. A. Antonenko, L. S. Pioro. Ed. by A. N. Alabovsky. – Kiev: Naukova Dumka, 1991. – 245 p. 2.

2. Elistratova Yu. V., Seminenko A. S., Minko V. A. Relevance of fouling models for diagnosing the state of plate heat exchangers // Bulletin of the Belgorod State Technological University named after V. G. Shukhov. – 2020, No. 10, pp. 33-40. DOI: 10.34031/2071-7318-2020-5-10-33-40.

3. Herre E. On chronaprzed korozjąi nstalacji s anitarnych // Warsaw, Arkady, 1972. 4.

4. Moklyak V. F. Heat transfer and hydrodynamics during condensation in thermosyphons in the two-phase mixture mode: diss. … Cand. of Engineering Sciences, 05.14.04 / Moklyak Vasily Feodosievich. – Kyiv, 1984. – 262 p. 5.

5. I. Khazaee, R. Hosseini, S. H. Noie. Experimental investigation of the influence of the geyser boiling phenomenon on the thermal performance of a twophase closed thermosyphon. I. Khazaee et al. // Applied Thermal Engineering. – No. 30 (2010), pp. 406-412.

6. Semena M. G., Kiselev Yu. F. Study of heat exchange processes in the heat supply zone of two-phase thermosyphons on freons-11, 113, 142, water and ethanol // Ing.-phys. journal. – 1978. – 35, No. 2. – P. 211-217.

7. Shcheklein S. E., Kostomarov V. M. On the mechanism of formation of a steam projectile in a narrow channel without forced circulation // High Temperature Thermal Physics. – 1982. – Vol. 20, No. 6. – P. 1203-1205.


Review

For citations:


Iakovlev L.O. Experimental investigation of the influence of inclination on the power of a thermosiphon heat exchanger (TPCT). Alternative Energy and Ecology (ISJAEE). 2024;(11):117-121. (In Russ.) https://doi.org/10.15518/isjaee.2024.11.117-121

Views: 33


ISSN 1608-8298 (Print)